This APC Smart-UPS is designed for IT professionals or network administrators to maintain business uptime and continuity. The 3kVA line interactive 2U rackmount UPS provides pure sine wave power to support critical electronics during power disruptions. It comes with IEC 320 C20 input, BS1363A British and Schuko CEE 7/EU1-16P input cables, 8x IEC 320 C13 and 1x IEC 320 C19 outlets, and 3x IEC jumper cables. It has a preinstalled Network Management Card for UPS network-based monitoring and management. The UPS comes with PowerChute Network Shutdown that provides graceful shutdown of physical servers, virtual machines, and HCI clusters. This UPS can connect to EcoStruxure IT or third-party centralized management platforms It provides surge protection against lightning strikes, power sags, brownouts and surges. The UPS has a 3-year warranty and the built-in lead-acid battery has a 2-year warranty. It is compatible with a dedicated user-replaceable battery, and the APC replacement battery cartridge helps restore UPS performance to the original specifications.
- Predicitive failure notification - provides early-warning fault analysis ensuring proactive component replacement
- Wide input voltage range - designed for harsh electrical environments to save battery life
- LED indicators - provide easy-to-read status of the unit and utility power conditions
- Boost and Trim Automatic Voltage Regulation (AVR) - eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress
- High online efficiency - reduces utility costs, generates less heat
- Energy meter - provides actual kilowatt hours of usage for energy conscious users
- Predictive replace battery date - dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning
- Intuitive LCD interface - provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys
- Single switched outlet group - single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding
- Sequenced network shutdown and reboot - customize network shutdown and reboot sequence of connected servers and UPSs
- Outlet group control - turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations
- Adjustable voltage sensitivity - provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications
- Adjustable voltage-transfer points - maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation
- Audible alarms - provides notification of changing utility power and UPS power conditions
- Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
- Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced
- Cold-start capable - provides temporary battery power when the utility power is out
- Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Network manageable - provides remote power management of the UPS over the network
- Battery failure notification - provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Safety-agency approved - ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment
- Serial connectivity - provides management of the UPS via a serial port
- Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
- User-replaceable batteries - increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
- Frequency and voltage regulation - gives higher application availability by correcting poor frequency and voltage conditions without using the battery
- Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
- Power conditioning - protects connected loads from surges, spikes, lightning, and other power disturbances
- Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
- Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
- Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced
- Disconnected battery notification - warns when a battery is not available to provide backup power
- Network manageable - provides remote power management of the UPS over the network
- Audible alarms - actively let you know if the unit is on battery, if the battery is low or if there is an overload condition
- LED status indicators - quickly understand unit and power status with visual indicators
- Serial connectivity - provides management of the UPS via a serial port
- Disconnected battery notification - warns when a battery is not available to provide backup power
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High online efficiency
Reduces utility costs, generates less heat.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Intelligent Card Slot
Customize UPS capabilities with management cards.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
Outlet group control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
Predictive failure notification.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Preinstalled network management card
Provides for remote management and control of the UPS over a network out of the box.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Safety-agency approved
The UPS is UL1778 Listed
Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs.
Serial connectivity
Provides management of the UPS via a serial port.
Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Wide input voltage range
Designed for harsh electrical environments to save battery life.